柴油发电机的蓄电池维修保养周期为每运行50小时进行一次:
1、用验电器检查蓄电池充电是否足够,否则应充电;
2、检查电池液位是否在极板上15MM左右,如果不够则加蒸馏水至上述位置:
3、检查电池接线柱是否被腐蚀或有打火痕迹,否则应修复处理或更换,并涂上黄油。
The maintenance cycle of the diesel generator battery is once every 50 hours of operation:
1. Use a voltage tester to check if the battery is fully charged, otherwise it should be charged;
2. Check if the battery level is around 15mm above the electrode plate. If it is not enough, add distilled water to the above position:
3. Check whether the battery terminals are corroded or have ignition marks, otherwise they should be repaired or replaced, and coated with butter.